Products
Hematology & Coagulation
Efficient, reliable and easy to use fully automated hematology analyzer for physician offices, clinics, urgent care centers, emergency rooms, hospitals or research labs and teaching hospitals.
H30 The Right 3-Part
Small sample volume makes it ideal for pediatric samples
Small reagent consumption with highest reagent efficiency
Minimum maintenance requirement and difficulty ever
Excellent performance with satisfying reliability and stability

Less Reagent Consumption
At least 50% lower than other competitors
10L diluent around 650 tests
Reagent consumption is a very sensitive issue to end-user side. Cost per test is defined by reagent consumption on each cycle as well as on maintenance, for profict-wise, higher reagent efficiency comes with higher profit per test.

Minimum Maintenance
Maintenance for analyzers between different system platforms and brands differ variably.
Daily, weekly, monthly and annually maintenance is the popular maintenance requirements.
But we, only require for weekly and annually base maintenancem which is also an extremely simple and cost effective maintenance list.
Maintenance Period | Maintenece by Customer | Maintenance by Field Service Engineer |
---|---|---|
Weekly | Bleach cycle | -- |
Monthly | None | None |
Quarterly (3900 cycles) | None | None |
Biannually(7800 cycles) | None | None |
Annually(15600 cycles) | None | Needle o-ring Piston greasing |
Three Years (46800 cycles) | None | Syringes block and pistons exchange |
Outstanding Flagging System
Test result provides two types of alarms - both Pathology and Monopoly. The Exclusive feature, only we can support such detailed and outstanding flagging system.
Flexible System Expandability
More compativle external printers
- Epson_M100/105/200/25
- Lexmark_CS310/ MS410
- HP LaserJet_P1102/1106/1108
- PCL 3/6 protocol
5 USB ports for data transmission, printer, barcode scanner and external keyboard
Unidiractional LIS/HIS connectivity.

Intelligent Internal Structure
Life-time tubing - Do not have to be touched ever
Modular design - lower maintenance difficulty
There is no high-voltage anywhere in the system
Liquids are separated from electronics
Vales are easy to reach

H50 Ingenuity for Entry 5-Part
H50, the new line of 5-part hematology analyzer, is the originality from EMD (Which is a joint venture od EDAN and BIT), where ingenuity meets advancement. With the Innovative technology, simple operations, fewer reagents, Intelligent fluidic system design and better performance, all in a smaller more affordable package that will fit any clinician budget and space.

Less Running Costs
Approximately 50% less reagent consumption
10L diluent can support around 580 tests

Minimum Maintenance
Only require for weekly and annually base maintenace, which is also an extremely simple and cost effective maintenance list.
Might be the lowest operation cost as well as maintenance difficulty for distributors.

Flexible System Expandability
More compativle external printers
Epson - M100/105/200/25
Lexmark - CS310/ MS410
HP LaserJet - P1102/1106/1108
PCL 3/6 protocol
5 USB ports for data transmission, printer, barcode scanner and external keyboard
Bidiractional LIS/HIS connectivity.

Ingenious Internal Structure
Life-time tubing - Do not have to be touched ever
Modular design - lower maintenance difficulty
There is no high-voltage anywhere in the system
Liquids are separated from electronics
Vales are easy to reach

Excellent Performance on Anti-aging Samples
The techonology delivers a lower sensitivity to sample age, allowing you to more freedom to organize your work.

Excellent Performance on Eosinophilia Samples
The combination of the flow-cell, the super blue LED and the proprietary reagents provide excellent differentation of WBC, even on Eosinophilia samples.

Improved Platelet Identification
The H50 counting aperture is only 5µm which is smaller than conventional counting aperture that is usually over 80µm. The smaller aperture is more sensitive than the bigger ones, even the small PLT can be detected because of the signal to noise ration is higher. This will significantly improve the identification of platelet.

Contact
Get in Touch
We'd love to hear from you.
Our Address
1225 Quezon Avenue, Quezon City, Philippines 1104
Email Us
info@lifelinediag.com
Call Us
+63 2 8376 5917